null
US
Sign In
Sign Up for Free
Sign Up
We have detected that Javascript is not enabled in your browser. The dynamic nature of our site means that Javascript must be enabled to function properly. Please read our
terms and conditions
for more information.
Next up
Copy and Edit
You need to log in to complete this action!
Register for Free
308309
CAPILLARY ELECTROPHORESIS
Description
undergraduate degree analytical chemistry Mind Map on CAPILLARY ELECTROPHORESIS, created by chaz_id89 on 28/10/2013.
No tags specified
analytical chemistry
undergraduate degree
Mind Map by
chaz_id89
, updated more than 1 year ago
More
Less
Created by
chaz_id89
about 11 years ago
120
0
0
Resource summary
CAPILLARY ELECTROPHORESIS
ELECTROPHORESIS: HOW DOES IT WORK?
differential migration of charged sp. in applied DC
rate depends on CHARGED:SIZE RATIO
migration rate ν= μeE
Annotations:
μe = electrophoretic mobility α = ionic charge 1/α = frictional factors (size & shape, viscosity) E = applied field strength
electric field strength related to magnitude and length over which
migration rate : ν= μe x V/L
Annotations:
V: voltage L: length of slab/capillary
Plate #: N= μeV/2D
Annotations:
D: diffusion coefficient of solute
RESISTANCE (joule heating)
V = I x R
Annotations:
I = current R = resistance
if use gel - produce heat. limit V applied for slab elect. ~500v
Capillary typically 10-100μm ID and 30-100cm long (large surface:volume ratio = better cooling)
P = I^2/R
Annotations:
P = power dissipation = amt heat produced long capillary and small cross sectional area = high R
voltages we can use in cap.ele. typical applied voltage 10-25kV = E of 100-400 Vcm-1 typical N = 100,000 –200,000(HPLC 5,000 –20,000)
ELECTROOSMOTIC FLOW
high V applied - buffer-filled-Si cap. - bulk liq twds CATHODE
pressure-induced
electroosmotic flow
EO Flow generally > electrophoretic migratn
buffer = mob. phase
EO flow = mob. phase pump
all analytes are swept through column regarding the charged (CATION - NEUTRAL - ANION)
electroosmotic flow velocity ν= μeoE
Annotations:
μeo= electroosmotic mobility
ion velocityν= (μe+ μeo)E
migration rate tm= l/ (μe+ μeo)E = IL(μe+ μeo)V
Annotations:
L= Length of capillary l = length to detector
N = 16(tm/W)^2
CE HARDWARE
Small vol- cap (4-5μL), injector/detector < 10nL (the result not concentrated)
Cap: fused silica, external coating of polyimide (flexibility & durability)
can reverse the polarity: anions elute first
Sample Injection
5 -50 nL
tips that can sample directly from cell/cell substructure
Can be automated
electrokinetic
Annotations:
Voltage--> sample flow with EO flow + ion movement Injects larger amts of more mobile ions
pressure
Detectors (= HPLC)
Optical
Problem with low volumes = short pathlength = low absorbance or fluorescence
modify cell to increase the pathlength
Z-cell
Annotations:
- path length 10 x the cap. diameter - increase path length -> decreases in peak efficiency = add spherical ball lenses btwn source-zcell-detector. - Increase sensitivity
Bubble cell
Annotations:
bubble formed near the end of the capillary
Multireflection cell
Annotations:
a reflective coating of silver is deposited on the end of the capillary
Adsorption & fluoro. (limits in conc terms, but equal or better in mass detection limits)
Indirect detection
for compounds that don't have suitable chromophore/molar absorptivity - add ionic chromophore in the buffer, see any reduction in that signal
Electrochemical
conductivity & amperometry
MS
small volume of flow rate (1uL/min) allow to couple w MS
common use of electrospray Ionisation (ESI)
use volatile buffer
CE/MS - use to detect proteins, DNA fragments n peptides. (large biomolecules)
APPLICATIONS OF CE
Capillary Zone Electrophoresis
small ions
cation separations- wall untreated, analytes flow with EO flow twrds cathode
Anions separation- wall treated, reversed EO flow twrds anode
molecular sp.
ions or non-ion (derivatization) - herbicides, persticides, proteins, aa. etc
- buffer composition is constant - ionic components migrate into zones (complete resolved zone have buffer between zones)
Capillary Gel Electrophoresis
performed in porous gel polymer matrix w a buffer mixture that fills the pores of the gel
types of gel : polyacrylamide polymer, agarose, methyl cellulose etc.
Capillary Isoelectric Focusing
separate amphiprotic sp. (aa, proteins - have weak COOH and AMINE gp.)
Annotations:
amphiprotic - sp in a soln is capable to donate or accept a proton.
buffer mixture that continuously varies in pH along its length
Media attachments
pressure-induced (image/png)
electroosmotic_flow (image/png)
cap.electrophoresis (image/png)
Z-cell (image/png)
bubble_cell (image/png)
multireflection_cell (image/png)
APPLICATIONS_OF_CE (image/png)
Show full summary
Hide full summary
Want to create your own
Mind Maps
for
free
with GoConqr?
Learn more
.
Similar
HPLC
chaz_id89
Τύποι ατομικής φασματοσκοπίας
mitsi23
Complexometria EDTA
Andrea Dacar
volumetria redox
Andrea Dacar
Capillary Electrophoresis (CE)
maddiebones
Chapter 26
isiylala
Principals and Practice of Analytical Chemistry
Sarah Jane Doran
Curva Titulacion Acido-Base
Andrea Dacar
Chapter 1
isiylala
Chap 5 - Quantitative Chemical Analysis
Raegan Ferro
MASS SPECTROMETRY
chaz_id89
Browse Library