HPLC
ADVANTAGES
SENSITIVE
CAN BE AUTOMATED
QUANT ANALYSIS
GOOD AT SEPARATING VOLATILE/THERMALLY LABILE COMPOUNDS
WIDE RANGE OF SUBSTANCES: in/organic, metals, ions, proteins, aa,etc.
SEPARATE ON SIZE, CHARGE, POLARITY, SOLUBILITY
CHIRAL SEPARATIONS
+ WIDE RANGE OF DETECTORS
RECOVER SAMPLES
DISADVANTAGES
EXPENSIVE, IMPURITY FREE SOLVENT USED.
MOVING PARTS & CONNECTIONS
OPTIMAL PERFORMANCE = KEEP IT RUNNING REGULARLY
Selection of LC modes
HPLC HARDWARE
Mixing controller
Mix difft solvents in precise ratios
reqd for: ISOCRATIC= constant solvent composition. GRADIENT= changing solvent composition
mix diffnt solvents in precise ratios
make sure that solvents are miscible
Injector
loop & valve configuration
load & inject positions
flat ended syringe - manual injection
ensure the loop is entirely filled - inject sample in 1 plug (~ 3 rinses)
Columns
generally = stainless steel
Analytical column: ID- 1-5mm, particle size- 3-5um, length- 35-250mm, plates/m-40000-70000
typical: 4.6mm x 5um x 150m = 10000 plates/column
Microbore or 'rocket'
short (30-75mm), thin (<4.6mm ID), small particles (3um) = faster
what's inside?
normal p.: polar stat, n-polar solvent (Si stst p.), 1:9 EtOAc:hexane mob p.
reverse p.: n-polar stat, polar solvent. (C18 stat p.), 15:85 MeOH:H2O mob p.
Monolithic (single crystal)
Polymer based, porous core, can control pore size
can run under lower pressure condition
better resolution, speed.
useful for larger mols.
How do you choose?
partition Chrom.
OPTIMISING CONDITIONS (3 parameters)
N : plate number
k : retention factor (strongly dependent upon make-up of mob. p.)
Annotations:
ideal range of k:2-10 complex mix: 0.5 - 20 α : can be changed by choosing diff column packing
α: selectivity factor
stat. p. is a 2nd liquid immiscible w liq mob. p
nonionic, polar w low/moderate mol mass. (ionic cmpds w derivatization &ion pairing)
change mob. p. composition = enhance separation
SOLVENT STRENGTH
Strong solvent: interacts strongly w solutes (often polar)
Polarity index (P') - based upon solubility in 3 separate solvents, -a measure of relative polarity, -higher P' = stronger
Mixed solvent
P(AB)' = *AP'(A) + *BP'(B) *A= volume fraction of solvent A
Normal Phase : k2/k1 = 10 ^(P'1-P'2)/2
Annotations:
if the ratio k2/k1 is large, need o have a big k2. if its small, - not resolved k2: final retention factor k1: initial "
Rev Phase: k2/k1 = 10 ^(P'2-P'1)/2
EFFECT OF MOB. P. ON α.
manipulate chemi nature: - proton acceptor, proton donor, dipolar interactions
Annotations:
start to add small amt of acid or base.
in rev p. : aq solns of : THF, acetonitrile, methanol.
ION PAIR CHROM. (ANALYSTES THAT MAY EASILY IONISE) -org acids, amines.
+ solvent modifier
org salt w large org counter ion
added in small conc
2 xplanations
counter ion pairs w analyte ion & this pair partition into stat. phase.
counter ion retained by the neutral stat. phase giving it a charge & get reversible ion-pair interactions w charged analyte
CHIRAL SEPARATIONS
ceramic Mg silicate
cyclodextrin
Pirkle type chiral stat. phase. Works on π acceptor/ π donor interactions some H bonding.
separate chiral compounds - enantiomers
either mob/stat phase reqd to be chiral.
complexation btwn chiral resolving agent w one of the isomers results in separation.
adsorption chrom.
Ion Chrom
active sites for cation exchange: sulfonate (strong acid) & carboxylic acid gp (weak)
Anionic exchangers - strongly basic tertiary amine gps / weak basic primary amine groups.
sulfonate based cationic resin equilibrated w NaOAc -injection of amines & alcohol
base materials: silica/zirconium/ organic polymer
with polymer columns: -know the pressure limitations of the packing, - packing may swell/contract in different solvents.
Size exclusion C. (gel permeation c.)
high mol mass sp.
packings (~10um) silica/polymer particles - a network of uniform pores
most stat. phases are crosslinked polymers
polymers may expand/contract in diffnt solvents.
Vtot = Vg + Vi + Vo
Annotations:
Vg= vol occupied by stat p. Vi= vol of solvent held in pores Vo= exclusion vol (vol solvent req to elute cmpnds too big for pores)
Vo = largest mol, Vi + Vo = smallest mols, Ve=Vo + KVi = intermediate mols (assume theres no mixing)
Annotations:
KVi : measure of th efraction of mols in the pores (K = Cs/Cm)
get finer separation by connecting columns in series. problems??
Affinity
bond an affinity ligand to a neutral solid support
ligand reversibly and selectively bind to analyte (Ab, enz inhibitor)
mobile phase hv dual roles:
promote strong binding (analyte & affinity ligand)
release bound sp. when other cmpds hv been eluted
can wash out by changing ionic strength or changing pH
Bonded Phases
PHENYL ETHER (extremely polar aromatics)
SILICA
NITRO (aromatics & double bonds)
PHENYL HEXYL (aromatics)
SULFONIC ACID (weak bases)
QUATERNARY AMINE (nucleotides, nucleosides, organic acids)
DIOL (rev: gel filtration of peptides & proteins) (normal: = to silica, x deactivated by H2O)
CYANO (slightly polar)
AMINO (normal: alternate selectivity to silica) (rev: carbs) (ion xchange: anions & org'c acids)
GENERAL STRUCTURE
DETECTORS
IDEAL REQMNTS
adequate sensitivity
stable & reproducible
linear response over several orders of magnitude
short response time, independent of flow rate
similarity in response to all possible analytes
non-destructive
minimum internal volume
compatible w liquid flow
3 basic types: optical, electrochemical, mass
1) REFRACTIVE INDEX
changes in DENSITY when analytes comesthrough cell
sensitive to turbulence, temp, solvent changes
used w isocratic systems only
fragile flow cells
2) EVAPORATIVE LIGHT SCATTERING DETECTORS (ELSD)
effluent nebulised into fine mist -- through laser & scattered radiation detected at right angle to laser
volatile mob. phase.
evaportn tube is heated, but temp kept low - labile cmpds not degraded
3) FLUORESCENCE
sample excited by radiation from source (Hg, Xe, laser)
resulting fluorescence detected at 90° to excitn beam
can derivatise sample (add fluoro tag)
4) UV & UV-VISIBLE (190-900nm)
filter variable, fixed wavelength, wavelength variable
UV-VIS needs 2 lamps: a UV lamp - Hg, a visible lamp - tungsten
5) PHOTODIODE ARRAY (PDA)
individual photosensitive elements : small silicon photodiodes (consist of a reversed-biased pn junction
6) ELECTROCHEMICAL
4 electrochemical techniques: amperometry, voltammetry, coulometry, conductometry
Specific applications
respond to sp that can be red/ox
output is electron flow generated
3 electrodes : working, auxillary, reference
7) MASS SPEC
common ionisation sources : electrospray ionisation (ESI), Atmospheric Pressure Chemical Ionisation (APCI)
Media attachments
selection_of_LC_modes (image/png)
monolithic_column (image/png)
hplc (image/png)
refractive_index (image/png)
ELSD (image/png)
fluoroscence (image/png)
fluorescence (image/png)
photodiodes (image/png)
Show full summary
Hide full summary
Want to create your own
Mind Maps
for
free
with GoConqr?
Learn more
.
Similar
Τύποι ατομικής φασματοσκοπίας
mitsi23
volumetria redox
Andrea Dacar
Complexometria EDTA
Andrea Dacar
Chapter 26
isiylala
CAPILLARY ELECTROPHORESIS
chaz_id89
Principals and Practice of Analytical Chemistry
Sarah Jane Doran
Curva Titulacion Acido-Base
Andrea Dacar
Chapter 1
isiylala
Chap 5 - Quantitative Chemical Analysis
Raegan Ferro
SURFACE ANALYSIS
chaz_id89
MASS SPECTROMETRY
chaz_id89
Browse Library