NCC Vol 1 – Section A QUIZ #1: General

Description

General overall test on Section A of Volume 1 of the National Construction Code (Australia). [Taken from 2012 edition of the NCC]
ian_watts
Quiz by ian_watts, updated more than 1 year ago
ian_watts
Created by ian_watts about 10 years ago
857
0

Resource summary

Question 1

Question
How many climate zones are there in Table A1.1 - Climate Zones for Thermal Design?
Answer
  • 12
  • 8
  • 9
  • 14

Question 2

Question
What type of climate would be classified as climate zone 8?
Answer
  • Temperate
  • Tropical
  • Cool Temperate
  • Alpine

Question 3

Question
How many classes of buildings are defined in the NCC?
Answer
  • 11
  • 8
  • 6
  • 10

Question 4

Question
Which of the following building classifications are dealt with in Volume 1 of the NCC?
Answer
  • Class 1
  • Class 2
  • Class 11
  • Class 4
  • Class 5
  • Class 6
  • Class 7
  • Class 8
  • Class 9
  • Class 10

Question 5

Question
What type of building is a Class 6 building?
Answer
  • Office
  • Residential
  • Shop/retail
  • A public building

Question 6

Question
What type of building is a class 9c building?
Answer
  • An aged care building
  • A public swimming pool
  • A gymnasium
  • There is no class 9c

Question 7

Question
A plant room, machinery room, lift motor room, boiler room or the like must be classified separately to the part of the building it is situated.
Answer
  • True
  • False

Question 8

Question
A building can have more than one classification.
Answer
  • True
  • False

Question 9

Question
If, after alterations or any other building work, two or more buildings cease to be connected through openings in the dividing walls, each of those buildings not now connected must comply with all the requirements for a single building. 
Answer
  • True
  • False

Question 10

Question
What is AS an abbreviation for?
Answer
  • Australian Standard
  • Architectural Standard
  • Architectural Script
  • Australian Script

Question 11

Question
Which of the following criteria do fire-resisting levels (FRLs) grade?
Answer
  • Structural adequacy
  • Integrity
  • Insulation
  • Cladding

Question 12

Question
Given the following FRL, 120/120/120; what criteria does the second '120' stand for?
Answer
  • Structural adequacy
  • Integrity
  • Insulation
  • Cladding

Question 13

Question
Given the following FRL, 90/90/90; what does each 90 mean?
Answer
  • 90 minutes
  • 90 hours
  • 90 newtons
  • 90%
Show full summary Hide full summary

Similar

ART AND ARCHITECTURE OF INDIA Images
Alice Gorodetsky
Architecture
lindsey.reynolds
Notre Dame
CECILIA SAAVEDRA
Medieval Art and Architecture
macorleto
Art Periods and Architectural Styles in the Czech Lands
katie.moberly
Colonial American Architecture
rosvain
architectural design
Nurul Aiman Abdu
FAMOUS ARCHITECTS
Richard Ayo
Week 1 Quiz
Joan Pasch
12- Late Modernism 1950-1980
rosvain
Architecture
maireadharris