Unit 203 Mock Installation Technology Questions

Description

Unit 203 Mock Sample Questions
carl tovey
Quiz by carl tovey, updated more than 1 year ago More Less
Oliver Balay
Created by Oliver Balay over 9 years ago
carl tovey
Copied by carl tovey over 8 years ago
112
0

Resource summary

Question 1

Question
Which one of the following directly affects all persons working with electricity in a working environment?
Answer
  • Electricity Safety, Quality and Continuity Regulations
  • BS 7671
  • Electricity at Work Regulations
  • Construction design and management Regulations

Question 2

Question
Which one of the following are non-statutory regulations?
Answer
  • Electricity at Work Regulation
  • Manual Handling Regulation
  • BS 7671
  • Provision and Use of Work Equipment Regulations

Question 3

Question
Which one of the following is a direct implication of not complying with statutory regulations?
Answer
  • Loss of earnings
  • Lost clients
  • Dismissal
  • Prosecution

Question 4

Question
The document showing the location of electrical equipment in an electrical installation is a:
Answer
  • specification
  • drawing
  • variation order
  • Gantt chart

Question 5

Question
Which one of the following diagram types does not show individual conductors or cables but shows the sequence of equipment?
Answer
  • Block
  • Circuit
  • Schematic
  • Bar chart

Question 6

Question
The symbol shown represents:
Answer
  • one-way switch
  • two-way switch
  • intermediate switch
  • pull switch

Question 7

Question
Which one of the following is the correct drawing scale where a wall, 4m in length, measures 8cm on a drawing?
Answer
  • 1:50
  • 1:100
  • 1:200
  • 1:500

Question 8

Question
A drawing is produced to a scale of 1:50 showing a socket outlet installed 3.5cm from the corner of a room. Which one of the following is the actual distance from the corner in the room?
Answer
  • 0.875m
  • 1.75m
  • 3.5m
  • 7m

Question 9

Question
A circuit installed to supply a fire panel would be identified as:
Answer
  • power and heating
  • data communication
  • control circuit
  • alarm and emergency system

Question 10

Question
The type of trunking that can be used as a circuit protective conductor is:
Answer
  • mini
  • PVC dado
  • steel
  • plastic

Question 11

Question
The insulation material of mineral insulated metal sheathed cables is absorbent; therefore the terminations must be:
Answer
  • watertight
  • correctly identified
  • fitted with a gland
  • fitted with a shroud

Question 12

Question
Additional cable supports should be provided in trunking where:
Answer
  • segregation is required
  • there are long vertical runs
  • trunking is made of plastic
  • the walls are made of lightweight block

Question 13

Question
Band I and Band II circuits can be enclosed in the same enclosure, provided that:
Answer
  • the current rating of all circuits does not exceed 10A
  • they are twisted around each other along the trunking length
  • every cable or conductor is insulated for the highest voltage present
  • there are the same number of Band I and Band II circuits

Question 14

Question
Which one of the following is the type of conduit fixing shown?
Answer
  • Cleat
  • Clip
  • Crampet
  • Saddle

Question 15

Question
Which one of the following symbols represents the rating factor for thermal insulation?
Answer
  • Ci
  • Ca
  • Cf
  • Cg

Question 16

Question
Which one of the following is the value of voltage drop, per ampere, per metre, for a 10mm2 multi-core flat thermoplastic 70°C cable, intended to supply a single phase circuit?
Answer
  • 44 mV/A/m
  • 11 mV/A/m
  • 4.4 mV/A/m
  • 2.8 mV/A/m

Question 17

Question
Which one of the following is the maximum current carrying capacity for a single core 6mm2 70°C thermoplastic insulated non armoured cable, enclosed in conduit on a wall installed for a single phase circuit?
Answer
  • 31A
  • 32A
  • 36A
  • 41A

Question 18

Question
Which one of the following is the value of voltage drop, in millivolts per ampere per metre, for a 4mm2 multi core thermosetting non armoured cable, intended to supply a single phase circuit?
Answer
  • 29 mV/A/m
  • 18 mV/A/m
  • 11 mV/A/m
  • 7.3 mV/A/m

Question 19

Question
Which one of the following devices is suitable for an installation supplying an X-ray machine in a hospital?
Answer
  • BS 3036 rewireable fuse
  • BS EN 60898 Type D
  • BS EN 60898 Type C
  • BS EN 60898 Type B

Question 20

Question
Which one of the following devices will disconnect in the fastest time if a short circuit current of approximately 400A occurred on a circuit?
Answer
  • 32A/30mA Type C RCBO
  • 32A Type B circuit breaker
  • 32A Type C circuit breaker
  • 32A Type D circuit breaker

Question 21

Question
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: • 4 x 1.5mm2 • 3 x 2.5mm2?
Answer
  • 16mm
  • 20mm
  • 25mm
  • 32mm

Question 22

Question
Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: • 8 x 1.5mm2 • 2 x 2.5mm2 • 2 x 4.0mm2?
Answer
  • 16mm
  • 20mm
  • 25mm
  • 32mm

Question 23

Question
Which one of the following is the conduit capacity factor to be used where a 25mm conduit has 2 bend in a 6m run?
Answer
  • 111
  • 182
  • 333
  • 600

Question 24

Question
The electrical system in which the connection to earth is by an earth electrode is:
Answer
  • TT
  • TN-S
  • TN-C
  • TN-C-S

Question 25

Question
Which one of the following earthing arrangements is shown in the diagram?
Answer
  • TN-C-S
  • TT
  • TN-C
  • TN-S

Question 26

Question
Which one of the following is the correct name of the component which links the main earthing terminal of an installation to the means of earthing?
Answer
  • Main protective bonding conductor
  • Supplementary equipotential bond
  • Earthing conductor
  • Functional earth

Question 27

Question
What is represented by Zs in the following formula: Zs = Ze + (R1 + R2)?
Answer
  • Total earth fault loop impedance
  • External earth fault loop impedance
  • Final circuit earth fault loop impedance
  • Combined resistance of the earth path

Question 28

Question
Which one of the following defines the term ‘main protective bonding conductor’?
Answer
  • The conductor which links the MET to an earth electrode
  • The conductor which links the MET to extraneous conductive parts
  • The conductor which links the MET to exposed conductive parts
  • The conductor which links the MET to the means of earthing

Question 29

Question
Which one of the following is the purpose of the main protective bonding conductor?
Answer
  • To raise extraneous conductive parts to the same voltage as the supply under overload
  • To raise extraneous conductive parts to the same voltage as the supply under earth fault conditions
  • To raise extraneous conductive parts to the same voltage as the supply under normal conditions
  • To raise extraneous conductive parts to the same voltage as the supply under transient fault conditions

Question 30

Question
Which one of the following is an exposed conductive part?
Answer
  • Metal-clad switch
  • Structural steelwork
  • Air conditioning ducting
  • Metallic oil service pipe

Question 31

Question
Which one of the following is metal cable trunking?
Answer
  • Earthed conductive part
  • Extraneous conductive part
  • Insulated part
  • Exposed conductive part

Question 32

Question
Which one of the following is an extraneous conductive part?
Answer
  • Metallic gas service pipe
  • Metal-clad twin socket outlet
  • Heavy duty steel conduit
  • PVC mini-trunking

Question 33

Question
Which one of the following methods of generating electricity uses fossil fuels?
Answer
  • Wave power
  • Solar
  • Gas
  • Wind

Question 34

Question
Which one of the following uses sunlight to generate electricity?
Answer
  • Photo-voltaic
  • Biomass
  • Wind
  • Air source heat pump

Question 35

Question
Which one of the following is a transmission voltage?
Answer
  • 400kV
  • 33kV
  • 11kV
  • 400V

Question 36

Question
Which one of the following is a typical distribution voltage for a medium-sized factory where a private sub station is located?
Answer
  • 230V
  • 400V
  • 5kV
  • 11kV

Question 37

Question
In which of the following parts of the electrical distribution network would a step-down transformer be located?
Answer
  • Power station
  • Pylon
  • Local distribution sub station
  • Inverter

Question 38

Question
Which one of the following describes the process of a solar photo voltaic system?
Answer
  • Solar power is used to ignite a biomass which heats up water
  • Solar power is collected by a solar panel which provides electricity
  • Solar power is collected by a solar panel which provides hot water
  • Solar power causes hot air to rise, rotating a generator that produces electricity

Question 39

Question
Which one of the following is a suitable use for rainwater harvesting?
Answer
  • Baths/showers
  • Toilet flushing
  • Drinking water
  • Cooking water

Question 40

Question
Which one of the following micro-generation systems requires the least maintenance once installed?
Answer
  • Micro-combined heat and power
  • Air source heat pump
  • Biomass
  • Solar thermal
Show full summary Hide full summary

Similar

Unit 203 Revision: Installation Technology Question Bank No.1
Oliver Balay
Unit 203 Mock Installation Technology Questions
Jamie Parslow-Williams
Unit 203 Revision: Installation Technology Question Bank No.1
Jamie Parslow-Williams
Unit 203 Revision: Installation Technology Question Bank No.1
james seaman
Unit 203 Revision: Installation Technology Question Bank No.1
dave love
Unit 203 Revision Question Bank No.2
Oliver Balay
Unit 308 Careeer's Awareness Revision
Oliver Balay
Unit 203 Revision Question Bank No.2
carl tovey
Unit 203 Revision: Installation Technology Question Bank No.1
Jamie Parslow-Williams
Unit 203 Revision: Installation Technology Question Bank No.1
Derek Pitcher
Unit 203 Revision: Installation Technology Question Bank No.1
Chantelle Browne