Who is credited with designing the reverse shoulder arthroplasty?
Charles Neer
Enrico Gervasi
Paul Grammont
Mario Randelli
What degree of retroversion is needed for an SMR anatomical shoulder?
10 Degrees
20 Degrees
30 Degrees
None of the above
What two ways below does the SMR system help to reduce the risk of scapula notching?
Using a metal back glenoid
Reversing the materials between the glenosphere and the liner
Distal fixation of the stem
Placing a chamfered edge on the liner
Why was there a need to invent the reverse shoulder?
Patients who had avascular neucrosis
Young patients who suffered trauma
Patients with Cuff tear arthropathy
To help prevent overstuffing of the joint
The 36mm Glenosphere is available in Polyethylene?
How many sizes of SMR Glenoid metal-back are available?
1
2
3
4
What makes the SMR metal back glenoid different to earlier designs of metal back components? (2 correct answers)
Trabecular Titanium Material
Multiple screw hole options
Concave shape
Large central peg
What Muscle is needed for a reverse shoulder replacement to work?
Deltoid
Biceps
Rotator Cuff
Triceps
What muscle group needs to be functioning for an anatomic shoulder replacement to work?
The SMR system offers cemented and cementless glenoid components?
When you have a deficient rotator cuff, what commonly happens to the humeral head when the deltoid is engaged?
Lateralises
Moves inferiorly
Moves superiorly
Nothing
What is Scapula Notching?
Metal ions released causing scapula to resorb
Poly debris caused by the poly liner articulating with the scapula and causing bone resorption
A naturally occurring phenomenon
Hyper extension of the shoulder
Which of the following trays are needed for an anatomic hemi shoulder replacement? (choose all correct answers
Common instrument Set
Endoprosthesis Instrument Set
Glenoid Instrument Set
Reverse instrument Set
SMR Reverse HP
Which of the following trays are needed for a reverse shoulder replacement using a 40mm Poly gleonsphere? (choose all correct answers)
When using the conical reamer to prepare for a reverse body, what tip can be used to ensure the reamer has been sunk deep enough?
Reading the gauge on the reamer shaft
Using a version rod
Inserting a 2.0mm k-wire in hole in the reamer near the cutting teeth
Eyesight
What sizes of peg are available for the cementless metal back?
Small-R
Small - Standard
Medium
Long
What is the advantage of an inlay platform system?
Easier surgical approach
Greater range of stem options
Reduces likelihood of overstuffing the joint
Reduces the likelihood of scapula notching
How old was the SMR system in 2017?
5 years
10 Years
15 Years
20 Years
True or false a Small- R poly liner can be used with a small metal-back glenoid component?
What additional step is needed after coupling (using the taper) an anatomic or reverse body to a stem?
Safety screw needs engaging
Safety screw needs removing
A second taper needs to be coupled
No further steps needed